Aid 4D probe; identify the probe via the ID code; switch the 4D generate signal by way of the electrical relay to produce the 4D probe perform normally. 4.two.2 Major board The main board might be divided into two sections: entrance-conclude of the primary board and back again-conclusion of the primary board.
Maximum 4 times tasking for a person transmitted beam, resulting in fantastic time resolution and better frame price.
Observe: About the check, the brightness adjustment arrives ahead of contrast. After readjusting the watch’s distinction and brightness, alter all preset and peripheral settings.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Slash off cable ties connecting the most crucial unit to the Show by diagonal reducing pliers, then pull out the corresponding cable plugs.
Written content Method Verify the battery periodically : a) Examine if battery may be charged normally when energy-on: That the current capacity is a hundred% or ability boosts immediately after a brief time signifies that the battery can be billed Typically.
Web site a hundred forty five Clean up control panel Tools: dry smooth fabric, mild soapy water Technique: Use dry gentle cloth to clean the area in the program. When the technique is filthy, moisten the tender cloth with mild soapy h2o and wipe off any stains. Use dry gentle fabric to eliminate any dampness and allow all hard surfaces to completely air-dry. Web page 146: Cleanse The Peripherals
Uncover greater diagnostic facts as a result of prolonged see of the anatomical composition on all convex probes.
iZoom™ permits exact viewing of impression from length iWorks™ Protocol helps standardize workflow and lessen Test moments
five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision Exam Phase: Do adjustments as the way in which in screening the most depth. History the gap by 20mm Each and every section to the longitudinal targets line utilizing the measurement caliper; Select the value with the best error (to 20mm), work out the accuracy utilizing the method below The measurement caliper ought to be positioned in the upper fringe of the focus on, Take note:... Site 79 Transverse geometric positioning accuracy Take a look at Phase: Include the scan floor of the phantom with h2o or couple gel, Carefully Make contact with the probe With all the scan surface Regulate the depth, generating the transverse targets for being exhibited within the picture. Adjust the main focus point being posited beside the transverse targets (the conventional isn't very clear) Adjust parameters like acquire, TGC, making each transverse targets for being Plainly exhibited. Web site 80 five.five.2.four Blackout Location Test Stage: Deal with the scan area with the phantom with h2o or couple gel, gently Get hold of the probe with the scan floor Modify the depth at a decreased benefit, and set the main target at the closest location to the scan floor. Reduce the value of parameters like AP, Gain right until the track record sound just may be observed. Web site eighty one: Software package Enhance And Servicing
The DP-50 Professional is undoubtedly an revolutionary, higher-overall performance Ultrasound System engineered to assist you obtain the insights you would like. The Program’s strong engine and higher-pace processing offer remarkable image high-quality and a complete info management Resolution.
Find out much better diagnostic facts by means of extended check out in the anatomical structure on all linear probes
Notice: In advance of inserting the connector in the probe port, inspect the connector pin. If your pin is bent, will not make use of the probe until it's been inspected / repaired / changed. Setting up Peripherals For your models of the supported peripherals, be sure to seek advice from “2.
Immediately after replacing the CPU module, essential file needs to be generated Yet again in accordance with the new MAC address and prepared into HDD of your machine. Or else, the configuration purpose of the solution will be misplaced. Immediately after eradicating the CPU module, Get rid of panhead screws with washers (12 Dp50rb login M3X6) set on the leading device box, you usually takes from the board. Site 118 Determine 8-29 Disassemble the User interface Assembly (one) Maintain the upper fringe of user interface assembly, and open up the user interface. Figure 8-30 Disassemble the Control Panel Assembly (two) Immediately after taking away a person countersunk head self-tapping screw PT3X10 preset over the control panel and get out the plug in the keyboard and the primary device connecting cables, you could potentially clear away the control panel assembly.
Observe: Make certain that you can pull out and thrust into your IO board sockets vertically when pulling out and assembling the IO board assembly about the position in the tackle. Take away panhead screws with washers M3X6 (4) used to secure the IO board, after which you could possibly take out the IO board. Site 116 Clear away panhead screws with washers (2 M3X6) which can be set on the leading unit, take out the higher baffle after which you can pull out two cables connecting the main board to the ability module assembly.